ARTYKUŁ

Przemysław Zalewski, Judyta Cielecka-Piontek, Magdalena Paczkowska

Development and validation of stability-indicating HPLC method for simultaneous determination of meropenem and clavulate potassium.
2014-03-27

A stability-indicating LC assay method was developed and validated for a simultaneous determination of meropenem and potassium clavulanate in the presence of degradation products formed during acid-base hydrolysis, oxidation and thermolysis. The isocratic RP-HPLC method was developed with a LiChrospher RP-18 (250 mm ◊ 4.6 mm, 5 μm) column and gradient elution of 12 mmol/L ammonium acetate and acetonitrile. The flow rate of the mobile phase was 1.0 mL/min, the detection wavelength 220 nm and the temperature 303 K. The method was validated with regard to linearity, accuracy, precision, selectivity and robustness, and was applied successfully for the determination of meropenem and potassium clavulanate separately as well as jointly in pharmaceutical formulations.
Keywords: liquid chromatography, meropenem, clavulanate potassium

Development and validation of stability-indicating HPLC method for simultaneous determination of meropenem and clavulate potassium.

148.01 kB | 21 grudnia 2017